PULLEY LOAD CELL
Features: robust, easy to install. Adjustable by two nuts with fine pitch. High resonance frequency, possibility of amplified analog output . Protection against overloads and centrifugal forces.
Applications: winding machines, unwinding machines, rotanting machines, planetary, pulling machines, any application that needs to measure the pull of cables, ropes etc.
Click to enlarge image
Material | Stainless steel/Aluminium |
Nominal load | 10, 500 N |
Limit load | 200 % F.S. |
Breaking load | 500 % F.S. |
Nominal load deflection | 0,1 mm |
Supply voltage | Maximum 18 V dc |
Sensitivity | 1 mV/V |
Output tollerance | 0,2 % F.S. |
Zero tollerance | 1 % F.S. |
Linearity | 0,2 % F.S. |
Hysteresis | 0,03 % F.S. |
Reapeatability | 0,2 % F.S. |
Input resistance | 350-360 ohm |
Output resistance | 350-353 ohm |
Insulation resistance | >= 2000 Mohm |
Creep (30 Minutes) | 0,03 % F.S. |
Thermal compensation | -10 / +40°C (14 / +104°F) |
Operating temperature | -20 / +70°C (-4 / +158°F) |
Temperature deviation zero | 0,003 % F.S. / °C |
Temperature deviation full scale | 0,002 % F.S. / °C |
Protection class | IP 54 |
Standard cable length | 5 m – 4 x 0,25 (shield not connected to the load cell body |
Type | SHIELDED CABLE 4C R5 PUR 4X0,25 |
Length | 5 m (body lead cell not connected shield) |
Red | + IN |
Black | - IN |
Green | + OUT |
White | - OUT |
General precautions to be followed in the installation and assembly of load cells: